How To Pass the H13-629_V3.0 HCIE-Storage (Written) V3.0 Exam?

Written by victoriameisel  »  Updated on: November 19th, 2024

Are you looking for comprehensive preparation materials for the H13-629_V3.0 HCIE-Storage (Written) V3.0 Exam? The latest H13-629_V3.0 HCIE-Storage (Written) V3.0 Exam Dumps have just been released by the Passcert team. These materials are meticulously crafted and contain real questions and detailed answers designed to help you pass your exam with ease. By using these H13-629_V3.0 HCIE-Storage (Written) V3.0 Exam Dumps, you can ensure that you are well-prepared and confident on the day of your test. By following these tips and utilizing the comprehensive materials available, you can confidently prepare for the H13-629_V3.0 HCIE-Storage (Written) V3.0 Exam and take a significant step towards becoming a certified storage expert.

HCIE-Storage V3.0 Exam

To excel in the HCIE-Storage V3.0 exam, candidates need to have a good command of key technical principles, planning and design processes, deployment implementation methods and tools, advanced O&M management, and troubleshooting of typical storage solutions, such as storage data backup and storage data migration. They should be able to design, manage, build, and develop high availability storage solutions, making them competent to become storage solution experts, storage architects, and other related positions. The certification is aimed at individuals who aspire to become experts in the storage industry, including data center storage system architects, ICT professionals, and Huawei channel engineers. It is recommended that candidates master the knowledge and skills of HCIA and HCIP in the storage domain and have at least five years of relevant working experience.

HCIE-Storage (Written) V3.0 Exam Information

Exam Code H13-629

Exam Name HCIE-Storage (Written)

Exam Type Written examination

Exam Format Single-answer Question, Multiple-answer Question, True or false, Short Response Item, Drag and Drop Item

Time 90 min

Passing Score/Total Score 600/1000

Exam Cost 300 USD

Language Chinese, English

HCIE-Storage (Written) V3.0 Exam Knowledge Points

Knowledge Points Percentage

Data Storage Technologies 20%

Data Protection Solution 50%

Data Migration Solution 10%

Data Storage Management and O&M 20%

Module 1: Data Storage Technologies

1. Flash Storage Technology Presentation

2. Data Protection Technology Presentation

3. Scale-Out Storage Technology Presentation

4. Hyper-Converged Infrastructure Technology Presentation

Module 2: Data Protection Solution

1. Data Protection Basics

2. Backup Solution

3. Active/Standby DR Solution

4. Active-Active DR Solution

5. Geo-Redundant 3DC DR Solution

6. Data Protection Solution Planning and Design

Module 3: Data Migration Solution

1. Data Migration Basics

2. Migration Solution Planning and Design

Module 4: Data Storage Management and O&M

1. Huawei Data Management System

2. Data Storage Management and O&M Practices

3. Storage System Troubleshooting

Share HCIE-Storage (Written) V3.0 H13-629_V3.0 Free Dumps

1. A maintenance engineer discovers that the fault indicator of a storage device is flashing. The management UI tells the engineer that a RAID group degradation alarm is generated becaus disk fault. The disk is then replaced and the fault is rectified. During this process, which of the following basic troubleshooting methods is used by the maintenance engineer?

A Logical reasoning

B. Phenomenon analysis

C. Replacement

D. Alarm analysis

Answer: D

2. Which of the following does not cause value-added service faults?

A. The replication links between storage devices are inconsistent.

B. LUNs are disconnected unexpectedly.

C. Logging in to a remote storage device through a serial port fails.

D. A storage pool of a remote storage device goes offline.

Answer: C

3. Formatting a newly-created LUN in a Huawei all-flash storage system fails. Which of the following is not the source of this problem?

A. Degradation or failure of the RAID group where the LUN resides.

B. Sudden disconnection between a host and the storage system.

C. Switching the owning controller of the LUN during the formatting.

D. Resetting the owning controller of the LUN.

Answer: B

4. Which of the following statements about the DME architecture is incorrect?

A. It is a distributed microservice architecture, providing high reliability.

B. It facilitates large-scale storage device management, allowing a single node to manage up to 16 storage devices.

C. It supports open northbound and southbound systems. Northbound systems provide RESTful and SNMP interface protocols as well as ecosystem plug-ins (such as Ansible) to interconnect with upper-layer systems, whereas southbound systems manage storage resources through open interface protocols such as SNMP and RESTful.

D. It takes over Huawei storage devices only.

Answer: D

5. Customer M plans to use eReplication to build a disaster recovery (DR) solution. Which of the following statements is incorrect about the configuration of eReplication DR service?

A. A remote server must be created.

B. Protection groups are created based on different application types.

C. A recovery plan needs to be created for data and service recovery.

D. A license for eReplication is required for building the DR system.

Answer: A

6. A company plans to deploy a disaster recovery (DR) system and requires that services run without interruption and service data be not lost when a data center-level fault occurs. The company plans to use a two-city three-DC geo-redundant architecture. Which of the following solutions meets the requirements?

A. Local HA architecture based on an active-passive mode.

B. Geo-redundant architecture based on a two-DC active-passive mode.

C. Geo-redundant architecture based on a two-DC mutual backup mode.

D. Geo-redundant architecture based on a two-DC active-active mode.

Answer: D

7. A company purchases a Huawei hybrid flash storage system. Hosts are connected to the storage system through Fibre Channel switches. Which of the following is the optimal configuration during Fibre Channel switch configuration planning?

A. Each zone contains only one host port and one storage port.

B. Each host requires only one optical fiber port to connect to a switch.

C. All ports of each Fibre Channel switch are in the same zone.

D. High-end Fibre Channel switches are always used to ensure network performance.

Answer: A

8. A company's service host runs the Linux operating system (for example, CentOS). Storage engineers need to use a Linux system performance monitoring tool to collect performance data. Which of the following operations is incorrect?

A. Use the top command to check the CPU usage.

B. Use the df command to check the storage space.

C. Use the iostat command to check the disk I/Os.

D. Use the free command to check I/Os on the network.

Answer: D

9. Huawei all-flash storage devices must be planned and designed before deployment. Which of the following does not need to be planned during storage networking?

A. Management network

B. Service network

C. IP address

D. Heartbeat network

Answer: D

10. Which of the following statements is incorrect about the protocol layer of Huawei scale-out storage products?

A. The block service supports the iSCSI protocol.

B. The object service supports access through $3/Swift.

C. The protocol layer supports access through HDFS.

D. The protocol layer does not support file access through NFS.

Answer: D


Disclaimer:

We do not claim ownership of any content, links or images featured on this post unless explicitly stated. If you believe any content or images infringes on your copyright, please contact us immediately for removal ([email protected]). Please note that content published under our account may be sponsored or contributed by guest authors. We assume no responsibility for the accuracy or originality of such content. We hold no responsibilty of content and images published as ours is a publishers platform. Mail us for any query and we will remove that content/image immediately.